Canopy cover effects on mean radiant temperature and land surface temperature in Antakya’s urban parks before the earthquake
Theoretical and Applied Climatology, cilt.157, sa.12, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 157 Sayı: 12
- Basım Tarihi: 2026
- Doi Numarası: 10.1007/s00704-026-06740-8
- Dergi Adı: Theoretical and Applied Climatology
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, IBZ Online, Aerospace Database, Artic & Antarctic Regions, BIOSIS, Environment Index, Geobase, Index Islamicus, INSPEC, Academic Search Ultimate (EBSCO), Natural Science Collection (ProQuest), Biomedical Reference Collection: Corporate Edition (EBSCO), Earth, Atmospheric, & Aquatic Science Collection (ProQuest), Materials Science & Engineering Collection (ProQuest), Technology Collection (ProQuest)
- Anahtar Kelimeler: ENVI-met, Remote sensing, Thermal regulation, Tree canopy, Urban microclimate, Urban parks
- Hatay Mustafa Kemal Üniversitesi Adresli: Evet
Özet
Urban parks are increasingly recognized as critical nature-based solutions for moderating urban microclimatic conditions in hot-climate cities. This study investigates how tree canopy cover relates to land surface temperature (LST) and mean radiant temperature (TMRT) in urban parks located within the pre-earthquake urban area of Antakya, Türkiye, combining satellite-based analysis with microclimate modelling. Using Landsat 8 imagery, LST values were calculated for July 2020–2022 across 102 parks. Based on mean LST values, ten parks representing contrasting microclimatic conditions were selected for detailed micro-scale analysis. Canopy cover was quantified using normalized difference vegetation index (NDVI)-derived metrics, and TMRT was modeled under current conditions and a scenario representing a 30% increase in canopy cover using ENVI-met. Park-level LST values ranged between 31.21 °C and 36.44 °C. Pearson’s correlation analysis showed a moderate negative but non-significant relationship between canopy cover and LST, while the relationship between canopy cover and current-condition TMRT was very weak and non-significant. Under the 30% canopy cover increase scenario, TMRT decreased across all ten modeling domains, with reductions ranging from 0.01 to 5.24 °C and a mean reduction of 1.751 °C. The paired-samples t-test indicated that the overall reduction in TMRT was statistically significant. The findings indicate that canopy cover alone does not fully explain the observed variation in LST and current-condition TMRT, while increased canopy cover produced a significant but site-specific reduction in modeled TMRT. This study provides a site-specific framework for evaluating canopy cover-based strategies within green infrastructure planning, offering insights for climate-adaptive urban design in Mediterranean cities.