Zero-shot detection of apical periodontitis on periapical radiographs using multimodal large language models: diagnostic accuracy and error patterns


ADIGÜZEL M., Ozeken F., Ozeken T.

BMC ORAL HEALTH, cilt.26, sa.1, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 26 Sayı: 1
  • Basım Tarihi: 2026
  • Doi Numarası: 10.1186/s12903-026-09026-7
  • Dergi Adı: BMC ORAL HEALTH
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, CINAHL, EMBASE, MEDLINE, Directory of Open Access Journals, Natural Science Collection (ProQuest), Biological Science Database (ProQuest), Biomedical Reference Collection: Corporate Edition (EBSCO), Health Research Premium Collection (ProQuest)
  • Hatay Mustafa Kemal Üniversitesi Adresli: Evet

Özet

Background The present study evaluated the diagnostic performance of three general-purpose multimodal large language models (MLLMs)-Claude 4.5 Sonnet, GPT-5.2 Thinking, and Gemini 3.0 Pro-in detecting apical periodontitis on periapical radiographs.Methods One hundred twenty periapical radiographs were included (60 apical periodontitis-positive and 60 healthy), retrieved from routine clinical records at a university dental clinic. Teeth with root canal fillings and radiographs showing metallic artifacts were excluded to minimize superimposition in the apical region. Two experienced clinicians independently assessed all images to establish the reference standard based on two-dimensional periapical radiographic interpretation without CBCT confirmation. Disagreements were resolved by consensus, and interobserver agreement was high (Cohen's kappa = 0.88). The same coded images were subsequently evaluated by the three MLLMs in separate sessions using a standardized prompt, without any example or training images. Model outputs were restricted to binary "present/absent" responses. Accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Differences among models were analyzed using Cochran's Q test (alpha = 0.05), followed by Bonferroni-adjusted McNemar tests.Results Gemini 3.0 Pro achieved the highest overall accuracy (71.67%). This performance was significantly superior to that of Claude 4.5 Sonnet (Bonferroni-adjusted p = 0.0015). Claude 4.5 Sonnet demonstrated very high sensitivity (95.00%) but low specificity (13.33%), reflecting a strong false-positive tendency. In contrast, GPT-5.2 Thinking showed high specificity (98.33%) with markedly reduced sensitivity (20.00%). Gemini 3.0 Pro maintained high sensitivity (95.00%) while achieving moderate specificity (48.33%). Positive and negative predictive values (PPV/NPV) were 52.29%/72.73% for Claude, 92.31%/55.14% for GPT-5.2 Thinking, and 64.77%/90.62% for Gemini 3.0 Pro.Conclusions Under zero-shot conditions, the evaluated MLLMs did not demonstrate sufficient reliability to replace clinical judgment in the detection of apical periodontitis on periapical radiographs. Although diagnostic performance varied among models, none achieved a level of diagnostic performance sufficient for independent clinical use. At present, these systems appear more suitable as clinician-supervised decision-support tools. Further research is needed to improve diagnostic reliability and validate performance across diverse clinical settings.